Walk-In Cold Chamber

Know More
Walk In Cold Chamber

Walk-In Cold chamber / Cooler, Temperature, Heating, Cooling.

Chambers Overview

Introduction to Walk-In Cold Chamber

It is constructed in compliance with DIN, MIL, IEC,IS 9000, IS.

Walk In Cold chamber / Cooler is intended for performing different type of test where the temperature of sample environment must be controlled within certain limits. The role of environment testing into examine and prove the suitability, reliability, durability of products through the exposure to the environmental effects of temperature. Acceleration of the environmental effects that these products will experience in nature is required.

Walk In Cold chamber / Cooler is intended for performing different type of test where the temperature of sample environment must be controlled within certain limits. Our policy of continual liaison with leading researchers ensures we maintain our premier position as suppliers of high quality Walk In Cold chamber / Cooler and associated facilities. Our Walk In Cold chamber / Cooler, were designed with Safety, Reliability, Ease of operating and ergonomically.

Main Features

  • Test space dimensions are 3000 litres to 50000 litres.
  • Temperature Range – 70° C to +20° C.
  • Temperature deviation +/-1° C.
  • Temperature Resolution 0.1° C.
  • Temperature Gradient +/- 1° C to 2° C.
  • Average Temperature Raise/Fall 1° C to 10° C.
Walk In Cold Chamber

Chambers Construction

Interior structure made of non frost vapour / air tight type. The high – gloss polished stainless steel test space is welded vapour tight, has well finished edges. it remains impervious to corrosion and easy to clean. Interior structure made of non frost vapour / air tight type. 16 Or 18 SWG 304 grade stainless Steel with adjustable / removable shelving. Outer external structure made of 16 Or 18 SWG CRCA /GI/ Stainless steel with electrostatic powder super fine coating finishing for a good appearance.

Insulation is environmentally friendly free of asbestos and CFC free mineral fiber insulation guarantees the best possible insulation values and hence, it will decrease the operating costs.

CFC free Foamed in place Poly Urethane Foam (PUF) pre-fabricated. 80 mm puff panel insulation only for dismantling ITWCC models.

Door hinges fitted on the right hand side of the chamber with front opening single door. Double lined ‘A’ grade silicon gasket on door as well as chamber body so that like proof tightens the door for better performance with multi pan glass viewing window. Defogger heaters provided with an auto cut – off as well as suitable illumination provided to view the specimen under test.

In ITWCC models flush mounted type door. Glass window for viewing inside. Positive cam lifts hardware. Safety release exit device for opening door from both the sides. Only for dismantling ITWCC models.

Performance

Air circulation within the chamber with suitable capacity of fan motor and impeller for uniform distribution of temperature and humidity to maintain within desired limits. High circulating air rates ensure even distribution of temperature. Only the impeller will be exposed in the conditioning plenum with drive motor from outside of the chamber. Condition plenum covered with a detachable type sheet for friendly maintenance of the chamber. Noise level is < 70db.

Quick responding jacket type air heaters are used for heating system to achieve the set value temperature. Highly uniform temperature distribution minimises variations in test results over multiple specimens. Air heaters are placed in such manner that, there is no direct heat radiation from the heaters on to the test specimen.

Water Cooled / Air-cooled mechanical type single stage non CFC refrigeration system / mechanical type cascade compression refrigeration system. Ozone friendly refrigerant with hermetically sealed / low power consumption high boosted semi sealed compressor provided and system is designed such a way that, safety protection against high / low pressure and temperature. Electronic auto expansion valve system for expansion mechanism. Water / Air cooled condenser. Plate fin type cooler. Refrigerant R404A & R23. Pressure measuring device provided for measuring suction and head / discharge pressure of refrigeration systems. HP / LP cutoff / Oil separators with oil return system.

Instrumentation System

Programmable controller using large screen display. Instrumentation package features flexible. Other functions are included user friendly operation with TFT LCD touch screen as well as key input, graphical display of program patterns, testing history trend grapes. A no. of programs & profile segments with ramp & soak duration provided for cyclic operation.

The controller is able to communicate with many different types of hardware using high speed RS 232/485 communications ports, networking and USB communications for fast downloads. Power failure recovery operation system.

Microprocessor PID single set controller for Temperature is available only in RE models.

P.T 100 sensor is measuring the temperature.

Safety Devices

Walk In Cold Chamber /Cooler equipped with an emergency stop switch. High reliability and operator safety. Easy protection of chamber and specimen in case of failure. Chambers stop if the door is opening as operator safety. European style design signal tower.

Control circuit over current protection. Thermal fuse. Adjustable adequate safety cut – out against high and low temperatures. Chamber door limit switch. Every electrical functional circuit is equipped its own safety facility which shuts down the functional circuit affected or the entire test chamber in case of a malfunction.

Model Number

Cable Port holes are located on the left or on the right side of the test chamber and shall be used for inserting measurement and control cables, other supply connections or additional equipment with rubber plug.

Standard specification shelves and shelf are added as required.

Drain out let pipe with suitable fittings.

Electrical connection 415 V AC +/- 10%, 3 phase/N/PE 50 Hz.

Model No.Temperature RangeTest space dimensions in liters.
ITWCC – 70 LO-70 °C to +20° C3000 Liter to 150000 Liter
ITWCC – 40 LO-40 °C to +20° C3000 Liter to 150000 Liter
ITWCC – 20 LO-20 °C to +20° C3000 Liter to 150000 Liter
ITWCC – 10 LO-10 °C to +20° C3000 Liter to 150000 Liter

Note: LO = Logic programmable Models.

Our Walk-In Cold Chamber Samples

Walk-In Cold Chamber

Isotech Technologies

Walk-In Cold Chamber

Isotech Technologies

Walk-In Cold Chamber

Isotech Technologies

Walk-In Cold Chamber

Isotech Technologies

Let’s Talk About your Requirements

Check with our team by submitting a simple form, Our team will get in touch with you soon..!

Call Us: (+91) 984-594-6739

    Testimonials

    ISOTECHPL Clients Review

    Industry to provide a comprehensive various range of products and services to the environmental test industry.

    Download PDF

    ISOTECHPL

    Frequently Asked Questions!

    Ans: A Walk-in Cold Chamber, also known as a walk-in cooler, is a large, insulated room that can be used to store or test products at low temperatures. Walk-in cold chambers are used in a variety of industries, including food and beverage, pharmaceutical, and electronics.

    Ans: Isotech Walk-in Cold Chambers are designed to provide precise temperature control, even at very low temperatures. This makes them ideal for storing or testing products that are sensitive to temperature changes. Isotech Walk-in Cold Chambers are also energy efficient and easy to operate.

    Ans: Isotech Walk-in Cold Chambers can be used for a variety of applications, including:
    • Storing food and beverages
    • Testing products for temperature stability
    • Simulating the effects of cold weather on products
    • Drying products
    • Storing chemicals and other hazardous materials

    Ans: Isotech offers a variety of Walk-in Cold Chambers to meet the specific needs of our customers. Our chambers are available in a variety of sizes, with temperature ranges from -40°C to 40°C. We also offer a variety of optional features, such as humidity control, lighting, and shelving.

    Ans: The best way to choose the right Walk-in Cold Chamber for your needs is to consult with an Isotech representative. We will be happy to help you assess your needs and recommend the best chamber for your application.

    Ans: The cost of a Walk-in Cold Chamber from Isotech will depend on the size, features, and options you choose. Please contact us for a quote.

    Ans: Isotech Walk-in Cold Chambers are easy to install. We can provide you with installation instructions or refer you to a qualified installer.

    Ans: Isotech Walk-in Cold Chambers are easy to maintain. We recommend that you clean your chamber regularly and have it inspected by a qualified technician once a year.

    Ans: Isotech offers a comprehensive warranty on all of our Walk-in Cold Chambers. Please contact us for more information.

    Ans: You can buy a Walk-in Cold Chamber from Isotech directly from our website or by contacting one of our sales representatives.