Environmental Chamber For TCCF-AWS Sensors

An Environmental Chamber for TCCF -AWS Sensor’s testing is a controlled environment capable of producing conditions that a product will encounter during its use.

TCCF-AWS Sensors

Environmental Chamber for TCCF -AWS Sensor’s testing chambers test the prolonged effects of a varied range of temperatures to examine the quality parameters of a product or part. It will use for calibration of Master sensor’s where the master sensors are using to measure the temperature simulations conditions in various conditions.

A test chamber is a managed and controlled environment used to test the endurance, stability, and practicality of equipment, products, and chemicals. It is a controlled enclosure that mimics the effects of environmental conditions a product may encounter during its usage. Programmed test chambers create extreme temperature variations, moist or humid conditions, and radical altitude variances.

Aside from environmental conditions, test chambers can be designed and set to push the limits of a product through the use of physical forces such as inertia, vibration, and destructive impact.

A ECTCCFAWS chamber is a mechanism that creates different environments to allow manufacturers to test their products to the harshest of conditions. It also enables them to see how their products react to variations in humidity. ITPL Chambers are able to test the various parameters of their products in the harshest of conditions.

The purpose of ECTCCFAWS chambers is to test the influence of varying environments on products to determine the length of their usefulness and at what point they will fail. The collected data assists engineers in adjusting their designs and selecting more resilient materials.

The different varieties of ECTCCFAWS chambers allow testing to be completed in a static or dynamic state depending on the required data and the type of product. ECTCCFAWS chambers are used as extended testing chambers to determine a specimen‘s reaction to elevated moisture conditions when exposed for weeks or months.

Temperature Parameters
a)Range-70°C to +140°C
b)Accuracy0.01°C
c)Uniformity0.5 to 1.0°C in the entire range or better
d)Stability0.1 to 0.5°C in the entire range
e)AeratorFin type
Humidity Parameters
a)Humidity Range10% to 95%
b)Humidity Accuracy±2% RH in the range of +10°C to +60°C
Heating System
a)Rate of heating5.0°C
b)Rate of cooling5.0°C
Refrigerator System
a)Cooling GasCFC Free R – 404A /R 23 /R 508
b)CondenserAir/Water cooled condenser
Controller system
a)Temperature controllerPLC enabled PID controller with web browser
b)DisplayOLED /TFT display for all set parameters
c)FanHigh performance air fan for working of chamber
d)Fan ControlDepending on operation status automatic adaption of Fan speed respectively.
e)Output of dataRS232 /R 485 USB /Ethernet / LAN connectivity
f)InterfaceTo computer interfaced with suitable software for reading/recording
Environmental Chamber Specifications
a)Inner Chamber Volume200- 6000 liters
b)Window viewing AreaMultipin glass viewing window Flat type defogger heater with auto cut off
c)Work space illuminationWith LED lamp
d)Inside Chamber MaterialSS 304 /316
e)Outside Chamber MaterialElectro Static Powder Coated
f)Electric Input Power Requirement3-phase, 50-60Hz, 415V
g)Welding QualityArc welding / Co2 / Dig
h)Hose ProvisionLeak proof for sensor connection
i)Performance of ChamberTo carry out steady state, cyclic test between specified temperature and Humidity. The RH and temperature set with minimum time as per set points
j)Measuring Interval, Measuring Mode & display time ResolutionProgrammable and store continuous data. It able to display all environmental parameters clearly on the front panel with good visibility, supported by backlight
k)Feed Through HoleThere will be feed through hole for electrical wire connections and inserting DUT or any other cable. The hole diameter should be at least 5 cm. The hole should be kept closed properly when not in use. There should be provision to place wires using proper washer/gasket for secure tightened connection during operation.
l)Protection / SafetyThermal cutoff, Electrical cutoff are required
Reference Temperature Sensor (One No.)
a)Sensor TypePT 100
b)Temperature Range-30°C to 100° C or better
c)Temperature Accuracy0.01° C or better
Temperature readout (Display) unit (separate unit to read the reference)
a)DisplayOLED/LCD/TFT display
b)Display ResolutionUp to three decimal places (0.001° C)
c)ConnectivityRS232/USB/LAN connectivity to computer
Reference Humidity Sensor (One No.)
a)Humidity Measuring Range5% to 95%
b)Accuracy of Humidity Measurement1%
Humidity Readout (Display)(separate unit to read the reference sensor)
a)Display TypeOLED/LCD/TFT display
b)Display ResolutionUp-to one decimal places (0.1%RH)
c)ConnectivityRS232/USB/LAN connectivity to computer